Medical titanium

Implementation of the standards: GB / T 13810-2007, ASTM F67, ASTM F136
Ingots for the production and processing of materials should be used to vacuum consumable arc melting or EB furnace plus vacuum consumable arc melting, melting times not less than twice.
2, from the power pole prohibit using TIG welding.
Chemical composition:
The chemical composition of the product should be consistent with the corresponding provisions of the grades in the GB/T3620.1, pure titanium, the hydrogen content of the of TC4 and TC4ELI swollen, not more than 0.010%. Demand-side re-examination, chemical composition allows the the deviation shall comply with the provisions of the GB/T3620.2.
Dimensions and tolerances for:
1, medical titanium plate Dimensions and tolerances shall comply with the provisions of GB / T 3621.
2 Medical titanium rod dimensions and tolerances shall comply with GB / T 2965 provisions.
3, medical titanium wire Dimensions and tolerances shall comply with the provisions of GB / T 3623.
Performance:
1, the mechanical properties of the product should be tested in the heat-treated sample blank sample recommended heat treatment regime: Titanium 550 to 750 ℃​​, TC4, TC4ELI and TC20 alloy 700 to 850 ℃, insulation 0.5h ~ 3h , air-cooled, plate wire can also be used to vacuum annealing. For before the heat treatment system to make the appropriate adjustments.
Description

Description

Implementation of the standards: GB / T 13810-2007, ASTM F67, ASTM F136
Ingots for the production and processing of materials should be used to vacuum consumable arc melting or EB furnace plus vacuum consumable arc melting, melting times not less than twice.
2, from the power pole prohibit using TIG welding.
Chemical composition:
The chemical composition of the product should be consistent with the corresponding provisions of the grades in the GB/T3620.1, pure titanium, the hydrogen content of the of TC4 and TC4ELI swollen, not more than 0.010%. Demand-side re-examination, chemical composition allows the the deviation shall comply with the provisions of the GB/T3620.2.
Dimensions and tolerances for:
1, medical titanium plate Dimensions and tolerances shall comply with the provisions of GB / T 3621.
2 Medical titanium rod dimensions and tolerances shall comply with GB / T 2965 provisions.
3, medical titanium wire Dimensions and tolerances shall comply with the provisions of GB / T 3623.
Performance:
1, the mechanical properties of the product should be tested in the heat-treated sample blank sample recommended heat treatment regime: Titanium 550 to 750 ℃​​, TC4, TC4ELI and TC20 alloy 700 to 850 ℃, insulation 0.5h ~ 3h , air-cooled, plate wire can also be used to vacuum annealing. For before the heat treatment system to make the appropriate adjustments.