Implementation of the standards: GB / T 13810-2007, ASTM F67, ASTM F136
Ingots for the production and processing of materials should vacuum consumable arc melting or the EB furnace plus vacuum consumable arc melting, melting times not less than twice.
2. Consumable electrode prohibiting the use of TIG welding.

Chemical composition
The chemical composition of the product should be consistent with the corresponding provisions of the grades in the GB/T3620.1, pure titanium, the hydrogen content of the of TC4 and TC4ELI swollen, not more than 0.010%. Demand-side re-examination, chemical composition allows the the deviation shall comply with the provisions of the GB/T3620.2.

Dimensions and tolerances for

1 sheet dimensions and tolerances shall comply with GB / T 3621 provisions.
2 bars Dimensions and tolerances shall comply with GB / T 2965 provisions.
3 wire dimensions and tolerances shall comply with the provisions of GB / T 3623.

Performance
The mechanical properties of the product should be tested in the heat-treated sample blank sample heat treatment system recommended for: pure titanium 550 to 750 ℃​​, TC4, TC4ELI and TC20 alloy 700 to 850 ℃, insulation 0.5h to 3h, air-cooled plate wire vacuum annealing can be used.
For before the heat treatment system to make the appropriate adjustments.

Description

Description

Medical titanium rod

Implementation of the standards: GB / T 13810-2007, ASTM F67, ASTM F136
Ingots for the production and processing of materials should vacuum consumable arc melting or the EB furnace plus vacuum consumable arc melting, melting times not less than twice.
2. Consumable electrode prohibiting the use of TIG welding.

Chemical composition
The chemical composition of the product should be consistent with the corresponding provisions of the grades in the GB/T3620.1, pure titanium, the hydrogen content of the of TC4 and TC4ELI swollen, not more than 0.010%. Demand-side re-examination, chemical composition allows the the deviation shall comply with the provisions of the GB/T3620.2.

Dimensions and tolerances for

1 sheet dimensions and tolerances shall comply with GB / T 3621 provisions.
2 bars Dimensions and tolerances shall comply with GB / T 2965 provisions.
3 wire dimensions and tolerances shall comply with the provisions of GB / T 3623.

Performance
The mechanical properties of the product should be tested in the heat-treated sample blank sample heat treatment system recommended for: pure titanium 550 to 750 ℃​​, TC4, TC4ELI and TC20 alloy 700 to 850 ℃, insulation 0.5h to 3h, air-cooled plate wire vacuum annealing can be used.
For before the heat treatment system to make the appropriate adjustments.

Shipping & Delivery

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat net

Vestibulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames.Consequat netus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac vestibulum amet elit